HPTLC Automated Multiple Development System

CAMAG®
AMD 2 System

The CAMAG AMD 2 System is a cutting-edge HPTLC chamber designed for advanced gradient development, solving complex separation challenges efficiently.
HPTLC Automated Multiple Development System

In a nutshell

high resolution, precision, and repeatability

The separation of complex samples is a challenging task for every chromatographic system, particularly when the sample components span a wide polarity range.

The AMD procedure offers an excellent solution as it allows stepwise gradient elution over increasing separation distances. As a result acids, bases, neutral, hydrophilic, and lipophilic substances can be separated in a single AMD run. This makes AMD suitable for a variety of applications.

The technique is frequently used in lipid analysis and in routine analysis of drinking water. Pigment formulations with a complex composition, resins as well as additives of mineral oil products are other typical applications of AMD analysis.

  • Automated multiple development
  • Stepwise gradient elution over increasing separation distances
  • Enhanced separation capacity
  • HPTLC glass plates (20 x 10 cm), only
  • Software-controlled with visionCATS

THE PRINCIPLE OF

THE AMD PROCEDURE

  • The HPTLC plate is developed repeatedly in the same direction
  • Each successive run extends over a longer solvent migration distance than the one before
  • Between runs, the solvent is completely removed from the developing chamber and the layer is dried under vacuum
  • Each successive run uses a solvent of lower elution strength than that of the one used before. In this way, a stepwise elution gradient is formed
  • The combination of focusing effect and gradient elution results in extremely narrow bands. Their typical peak width is about 1mm. This means that, with the available separation distance of 80mm, up to 40 components can be completely resolved, i.e with base line separation
  • With visionCATS the AMD 2 can be IQ/OQ qualified and used in a cGMP environment. Operated with the mentioned software, the AMD 2 supports compliance with 21 CFR Part 11.

The AMD 2, like other software-controlled CAMAG instruments, communicates with visionCATS. The gradient, made from up to 5 solvent bottles, is defined by input into a table in visionCATS. Gradient and solvent migration distance for each run can be shown graphically for verification. Then all individual runs of the developing program are performed fully automatic and monitored by visionCATS.

SEPARATION OF VARIOUS

RHUBARB SAMPLES BY AMD 2

HPTLC chromatogram of rhubarb under UV 366 nm, derivatized with Natural Product reagent; AMD gradient in 10 steps: methanol – dichloromethane (40:60) to (10:90) in 9 steps, 40 mm solvent migration distance, then one isocratic step methanol – dichloromethane (10:90) over 70 mm solvent migration distance

AMD 2 uv366 rhubarb

Technical specifications

  • Plate types
    TLC/HPTLC glass plates 20 x 10 cm
    Glass thickness 1 mm
    Layer thickness up to 250 µm
  • Nitrogen or clean air pressure
    4.5–6 bar (60–90 PSI)
  • Nitrogen consumption
    Approx. 1 L / gradient step
  • Gas volume of chamber
    Approx. 550 mL
  • Environment temperature
    15° – 30° C
  • Solvent front detection
    CCD, accuracy better than ± 1mm
  • Number of developing steps
    Max. 99
  • Power connection
    100 V–240 V; 50/60 Hz
  • Dimensions (W x D x H)
    430 x 500 x 360 mm (550 mm incl. bottles)
  • Weight
    31 kg

What you need to get started

Ordering Information

Discover our comprehensive range of packages and make your selection today

Interested in the product?

Reach out to your local distributor and enjoy faster, improved results at reduced costs.

X
Phone:
Web:
or
Leave a message
Download

Related documents

Download manuals for in-depth device guidance
Instruction Manual
July 17, 2023
Declaration of Conformity
September 8, 2022
Brochure AMD 2
April 1, 2019