Skip to main content

CAMAG®
TLC

Devices for conventional TLC


In a nutshell

TLC equipment for qualitative analysis

TLC is a reliable and cost-effective method for separating and identifying components in complex samples, making it a cornerstone of qualitative analysis across industries such as TCM, herbal drugs, pharmaceuticals, food, and environmental science.

CAMAG provides specialized TLC tools for qualitative analysis, designed to optimize every stage of the process.

By integrating CAMAG’s TLC tools for qualitative analysis into your laboratory workflows, you can achieve efficient, accurate, and reliable chromatographic results.

  • Precise and reproducible results
  • Manual or semi-automatic sample application
  • High-quality development chambers
  • Easy-to-use equipment
CAMAG® Linomat 5

CAMAG® Linomat 5

With the Linomat 5 samples are sprayed onto TLC/HPTLC plates in the form of bands with nitrogen or compressed air. Application is automatic, only changing the syringe (filling, inserting and rinsing) is manual. The Linomat 5 is suitable for small sample throughput.

  • Semi-automatic application
  • Application of spots or bands
  • Data input through visionCATS software or keypad
CAMAG NANOMAT 4

CAMAG® Nanomat 4

The Nanomat 4 is a device for contact transfer application using capillaries. The actual sample dosage is performed with a disposable capillary pipette, which is precisely guided, thus ensuring that the chromatogram can be documented and evaluated automatically according to a programmed pattern. The Nanomat 4 is suitable for any plate format up to 20 x 20 cm.

  • Manual sample application
  • Application of spots by contact transfer
  • Precise positioning to apply a defined pattern
CAMAG SMARTCUT

CAMAG® smartCut

The smartCut allows cutting of TLC and HPTLC glass plates in defined pieces of any format. The sensitive layer is not destroyed and smooth edges are the result.

  • Cuts glass plates with a thickness up to 3 mm
  • Easy on the sensitive layer
  • Prevents offcuts and thus saves money
HPTLC Plates

  • Pre-coated TLC plates on a support of glass or aluminum
  • Layer thickness 200 or 250 µm
  • Available in the formats 10 x 20 cm or 20 x 20 cm
CAMAG TEST DYE MIXTURES

Test Dye Mixtures

Test dye mixtures are useful for functional checks on individual steps in the TLC/HPTLC procedure and for studying the influence of specific parameters.
multipurpose-spotting-guide_800x800

Multipurpose Spotting Guide

The Multipurpose Spotting Guide is used for setting up chromatograms on conventional 20 x 20 cm layers.
disposable-glass-capillaries_800x800

Disposable Glass Capillaries

Designed for manual sample application of 0.5, 1, 2, 5 or 10 μL and packed in color coded vials, the Disposable Glass Capillaries are hand-held and can be positioned with the Multipurpose Spotting Guide.

CAMAG® Twin Trough Chamber

Twin Trough Chambers offer several ways to specifically affect the TLC/HPTLC separation in order to improve it.

  • Glass tank with two troughs for manual development
  • Available in the formats 20 x 10 cm, 20 x 20 cm, and 10 x 10 cm
  • Steel or glass lid
camag-flat-bottom-chamber_800x800

CAMAG® Flat Bottom Chamber

The Flat Bottom Chambers permits the development of the plate under conditions of partial or complete saturation of the gas phase with solvent vapors. The degree of layer pre-saturation cannot be controlled unless additional accessories are used.

  • Glass tank with flat bottom for manual development
  • Available in the formats 20 x 20 cm and 10 x 10 cm
  • Steel or glass lid

CAMAG® Horizontal Developing Chamber

In the Horizontal Developing Chambers, plates can be developed in sandwich as well as in unsaturated and saturated chamber configuration. The chamber is suitable for all kinds of solvents.

  • Chamber for horizontal development
  • Development from both plate sides possible to double the number of samples
  • Low solvent consumption
camag-smartalert_800x800

CAMAG® smartAlert

The smartALERT is used for dependable monitoring of TLC/HPTLC plate development in a vertical glass developing chamber.

  • Enables that the chromatography is stopped at the set migration distance
  • Gives acoustic and visual notice when the development is finished
  • Compatible with glass chambers and glass plates at the formats 20 x 20 cm, 20 x 10 cm, 10 x 10 cm
camag-hptlc-vario-system_800x800

CAMAG® Vario System

Development with six different developing solvents can be tested side by side.

  • Development with six different developing solvents can be tested side by side
  • Sandwich as well as tank configuration can be simulated
  • Six different conditions of precondition can be tested simultaneously
camag-hptlc-sprayer_800x800

CAMAG® TLC Sprayer

The TLC Sprayer is used for manual spraying of derivatization reagents onto TLC plates.

  • Easy to use, with electro-pneumatic spray function
  • Formation of fine aerosol with particles of 0.3 to 10 µm
  • Low reagent consumption
camag-tlc-plate-heater3_800x800

CAMAG® TLC Plate Heater 3

The TLC Plate Heater 3 is a device for heating TLC/HPTLC plates, permitting the optimal heating during the derivatization reaction. It features a NEXTREMA® heating surface which is resistant to all common reagents and is easily cleaned.

  • For uniform heating of TLC/HPTLC plates
  • Temperature selectable between 25 and 200 °C
  • NEXTREMA® heating surface (resistant to all common reagents)
CAMAG GLASS REAGENT SPRAYER

CAMAG® Glass Reagent Sprayer

This all glass reagent sprayer is an alternative to the CAMAG® TLC Sprayer. It comes with a rubber pump but may also be operated from a compressed air or nitrogen supply.

  • For manual spraying of all common derivatization reagents
  • Chemical-resistant
TLC Visualizer

CAMAG® TLC Visualizer 3

The TLC Visualizer 3 is a high-end imaging and documentation system with superior performance in white light, long-wave UV (366 nm) and short-wave UV (254 nm) ensuring illumination with maximum homogeneity.

  • Maximum illumination homogeneity in white light, UV 366 nm and UV 254 nm
  • High-performance industrial camera with CMOS image sensor
  • Image-based evaluation
CAMAG UV Cabinet

CAMAG® UV Cabinet 4

The UV Cabinet 4 is designed for inspecting thin-layer chromatograms or other objects under UV light in absence of ambient light.

  • Two UV tubes for illumination (UV 254 nm & UV 366 nm, each 8W)
  • Minimum space requirements through small footprint
  • Eyes protected through UV filter in the viewing window
CAMAG UV Lamp

CAMAG® UV Lamp 4

The CAMAG UV Lamp 4 is inspecting thin-layer chromatograms or other objects under UV light in a TLC laboratory.

  • Two UV tubes for illumination (UV 254 nm & UV 366 nm, each 8W)
  • One button operation for each UV tube
  • Homogeneous illumination
CAM_TLC-MS_Interface-2

CAMAG® TLC MS-Interface 2

The TLC-MS Interface 2 enables users to directly analyze zones from TLC and HPTLC plates by Mass Spectrometry. A substance confirmation can be obtained in less than a minute.

  • Rapid and contamination-free elution of selected zones
  • Direct transfer to any mass spectrometer
  • Plug & play installation

Interested in the product?

Reach out to your local distributor and enjoy faster, improved results at reduced costs.

X
Phone:
Web:
or
Leave a message